Description
5200 Digital Radiography System
IMPROVED ERGONOMICS
The Carestream Kodak Rvg 5200 is the perfect choice for those looking to take the first step into digital dental radiography and imaging. An ideal solution for intraoral imaging needs, the easy-to-use sensor allows users to capture exceptional images quickly and easily. The image quality of the RVG 5200 sensor is the same or higher than other intraoral sensors and cameras in its class—so there is no need to sacrifice image quality for affordability.
INDICATION:
Used to produce images immediately on the monitor post-exposure.
 ADVANTAGES:
The Carestream RVG 5200 makes image acquisition fast and easy.
The captured images appear on your screen in seconds.
Simply position, expose and view.
If you encounter any problems during positioning, there is no need to rearm the sensor, the user-defined image processing tools allow you to program new default settings, either by using the pre-set tools or defining your own.
Fratures:
IMPROVED ERGONOMICS
Newly redesigned cable.
20% thinner diameter reduction in cable thickness.
Teflon lining reduces the friction of cable wires.
Improved flexibility.
The weaving of alloy mesh cable shielding optimized for flexibility.
RELIABLE BY DESIGN
Reinforced cable connection points are injection molded to increase strength over the previous generation of the RVG sensor.
Sensor cable attachment.
Connection to USB plug.
Higher uptime with lower service costs.
BUILT TO LAST
Thanks to rigorous design and testing, all RVG sensors provide maximum durability and flexibility. Completely waterproof, RVG sensors can be safely submerged in disinfectant for improved infection control.
The shock-resistant cases and silicon padding offers protection from falls, bites, and other damage, allowing them to stand up to even the toughest day in the operatory. In addition, protective lead layer helps to prevent damage due to repeated high exposure ensuring a long lifespan with an attractive return of investment.
AN AFFORDABLE, HIGH-QUALITY INTRAORAL SENSOR
As an entry point into dental digital radiography, the RVG 5200 system is not only easy to use but also remarkably powerful. The image appears immediately upon acquisition, allowing you to save valuable time and focus on what’s important – your patient.
No longer have to sacrifice image quality for affordability.
ENHANCED WORKFLOW
Workflow is optimized to the extreme: POSITION. EXPOSE. VIEW.
No need to activate the sensor prior to image acquisition.
RVG sensors are always ready to acquire images.
The image is displayed within seconds after X-ray exposure.
TWAIN COMPATIBILITY
TWAIN compatibility means the sensor can be integrated with almost any imaging and dental practice management software, including Carestream Dental practice management software.
ENHANCED PATIENT COMFORT
The RVG 5200 sensors ergonomic design makes positioning a breeze, while rounded camera ensures a more comfortable examination for patients. The sensors rear entry cable also assists in positioning and further improve dental care.
Specification :Â
TECHNICAL SPECIFICATION OFÂ CARESTREAM KODAK RVG 5200 DIGITAL RADIOGRAPHY SYSTEM:
Technology -SuperCMOS Scintillator Optical Fiber
Pixel size -19 μ
True (measured) resolution -16 lp/mm
Active area -22,2 x 29,6 mm
Overall dimensions –27,6 x 37,7 mm
Sensor plate thickness -7, 3 mm
Gray scale –4096 grey levels (12 bit s)
Input voltage (from USB interface) -5V
Direction of Use:
How to installation :
Unpacking and Inspection:
Carefully unpack the RVG 5200 system and inspect all components for any damage during transportation.
Hardware Setup: Connect the RVG sensor to the USB plug on your computer using the provided cable. Ensure a stable and secure connection between the sensor and the computer.
Driver Installation: Install the necessary drivers for the RVG 5200 system. These drivers are typically provided on a CD or can be downloaded from the manufacturer’s website.
Software Installation: Install the RVG imaging software on your computer. Follow the installation instructions provided with the software.
Calibration (if required): Some systems may require calibration. Follow the calibration steps outlined in the user manual or software guide.
Integration with Practice Management Software (if applicable):
If you are integrating the RVG 5200 with practice management software, follow the specific instructions provided by the software vendor.
Testing:Â Test the system by capturing a sample image to ensure proper installation and functionality.
How to use:
Positioning: Use the ergonomic design of the RVG 5200 sensor for accurate positioning. The rear entry cable may assist in positioning.
Exposure: Activate the X-ray machine to expose the image. The RVG 5200 is designed for immediate image acquisition, so there’s typically no need to activate the sensor separately.
Image Acquisition: The captured images should appear on the monitor screen within seconds after exposure..
Image Processing (if needed): Utilize the user-defined image processing tools provided by the software for customization. This can include adjusting contrast, and brightness, or applying filters.
Integration with Imaging Software: If using third-party imaging or practice management software, ensure proper integration through TWAIN compatibility.
Patient Comfort: Leverage the ergonomic design to make the examination more comfortable for the patient.